********************************************** Inductor, capacitor, frequency meter. ********************************************** http://www.measur.narod.ru Copyright (c) Potenko Alexander, 2000-2002 E-mail: measur@narod.ru; Technical features. =================== Range of measurement inductor............. 0.05 uH - 2 H Range of measurement capacitor............ 0.5 pF - 20 mF Range of measurement frequency............ 5 Hz - 10 ìHz Amplitude ................................ 0.15 v - 25 v Inaccuracy of measurement, (not more)..... 5 % Choice of limit of measurement L ......... automatic, manual Choice of limit of measurement C ......... automatic, manual Choice of limit of measurement F ......... manual Connected To free COM port of the computer. Adjustment. =========== Adjustment begin in frequency measurement mode (SB1 out-of-work): having included first range of measurement give voltage +10Â on resistor R18, beforehand having disconnected its from R17 and conclusion 6 microcircuits D10, and changing a capacity Ñ6 obtain 4400-4500Hz. Then, having restored join R18, meter translate in capacity measurement mode (1 range). Connect capacitor a capacity 30-70pF and replaceable resistor R17 variable (divisor =40 lines 16 Lcfmeter.ini), obtain evidences (+-2pF). Install constant R17 resistor and changing a period of measurements (line 20 Lcfmeter.ini) obtain evidences of meter corresponding nominal value of master capacity. Include an inductance and changing a divisor (line 6 Lcfmeter.ini) obtain evidences of meter corresponding nominal value of inductance. Adjustment fmeter. Installing maximum sensitivity by changing a resistor R5. Prescribing generator is used For the extension of range of measurement with the changeable frequency (SB2), in the program a switching 1-5 ranges on 6-10 is realized by keys Ctrl-z, Ctrl-x. Evidences corresponding master capacities and inductances in ranges 6-10 obtain a changing the corresponding divisors (line 8, 18).